![]() |
![]() |
![]() |
|
|||||||||||||
| |
|
|
|
|
||||||||||||
| |
|
|
|
|
|
|
|
|||||||||
| |
|
|
|
|
|
|
||||||||||
| |
|
|||||||||||||||
| |
|
|||||||||||||||
| |
|
|
|
|||||||||||||
| |
|
|||||||||||||||
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SELECT FS-1233 FOAM STICKS SELECT FS-1233 STICKS are water-soluble
sticks containing a combination of surfactants and friction reducer. Natural gas bubbling through the
water-column, surfactants and friction reducer produces foam which can help
remove water from watered-up gas wells. PRODUCT USES SELECT FS-1233 STICKS are
primarily used to remove water from gas wells and increase gas production. The foaming action decreases the hydrostatic
back-pressure which increases gas production that further enhances the foaming
action until the well unloads. SELECT FS-1233 STICKS can be
used to remove fluid from gas-condensate wells and flowing oil wells. For gas-condensate wells with more than 75%
condensate, it is recommended to use OIL FOAM STICKS™. SELECT FS-1233 STICKS can be
used to increase the swabbing efficiency and life of swab cups. SELECT FS-1233 STICKS contain a very slick
friction reducer. The extremely slick
coating along with the foaming action increases efficiency and life of the swab
cups and allows the well to flow easier.
The perforations are often cleaned as a result of the surfactants and
swabbing action. SELECT FS-1233 STICKS are
used in water injection wells in combination with ACID STICKS® to
help reduce injection pressures.
Surfactants contained in SELECT FS-1233 STICKS can help remove oil
coatings on scale. This helps the ACID
STICKS® react with the exposed scale. PRODUCT ADVANTAGES SELECT FS-1233 STICKS are an
economical way to remove water from gas wells without using expensive well service
operations such as swabbing, jetting with coiled tubing, or installing
artificial lift and siphon strings. TREATMENT DETERMINATION & PROCEDURE FOR WATER
REMOVAL The number of SELECT FS-1233
STICKS to be used is based on the volume of water above the perforations. Field tests indicate that the best results
were achieved by using a larger initial slug treatment of ½ to 1 percent by
weight of SELECT FS-1233 STICKS to water above the perforations. A treatment of ½ to 1 percent by weight would
require 1.75 to 3.50 LB of stick per BBL of water.
SELECT FS-1233 STICKS CONTINUED FROM FRONT NOTE: This amount is recommended
for an initial slug treatment. In many
cases, removing the top few hundred feet of fluid may be sufficient to allow
the production of natural gas to blow out the remaining fluid in the well. To determine the optimum amount for periodic
treatments you may choose to gradually reduce the initial treatment amount
until the most economical point is reached.
Periodic treatments with SELECT FS-1233 STICKS may be necessary to
prevent production decline due to the gradual water build-up. It is much easier to maintain gas production
with regular insertion of SELECT FS-1233 STICKS than it is to kick off a dead
well. Gas bubbling through water is
necessary to create foam. If a well is
totally dead, GAS STICKS™ may be used in conjunction with SELECT FS-1233 STICKS
to provide agitation energy. THE MOST COMMON PROCEDURE is to shut-in the well and drop sticks through a
lubricator. Wait 45 seconds or until
sticks contact top of fluid then slowly return well to normal production. Repeat procedure if or when it becomes
necessary. FOR HIGH RATE WELLS (after
sticks have contacted the top of fluid) flow well at about 25% of pretreatment
rate for about 20 minutes or until foam reaches surface then return to normal
rate. FOR SHALLOW OR LOW RATE WELLS
leave well flowing while dropping sticks if possible. PRODUCT SPECIFICATIONS The stick will normally
dissolve in 20 to 80 minutes depending on temperature, salt content, and
relative water motion. SELECT FS-1233
STICKS are 100% soluble in water and dispersible in oil. The melting point of the sticks is
120ºF. The stick will dissolve in water
in wells with BHT below 120º (just at a slower rate). Lab tests indicate the dissolving rate in
moving 50,000 PPM brine water to be 72 minutes @ 100º, 25 minutes @ 120º, 8 minutes
@ 140º, and 3 minutes @ 180º. The
dissolving time will decrease if the sticks are broken before dropping or if
they break upon impact with the top of the fluid. Specific gravity is 1.10. Falling rate through fresh water is
approximately 100 feet per minute. Gas
moving up tubing will often change falling characteristics. PRODUCT PACKAGING
CAUTION: As with all industrial
chemicals, contact with eyes or skin should be avoided (see MSDS). Wash thoroughly with water. Sticks should be stored in a cool dry place. Always remove stick from plastic bag or
split cardboard tube
before using. Bag or cardboard
tube can be used as a glove to avoid contact with hands. DISCLAIMER OF LIABILITY The information in this
bulletin is believed to be accurate, however all recommendations are made
without warranty, since the conditions of use are beyond Select Industries, Inc.
control. Select Industries, Inc.
disclaims any liability in connection with the use of information, and does not
warrant against infringement by reason of the use of any of its’
products in combination with any other material or in any process. |
|
|
|
|
|
||||||||||||||
![]() |
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
![]() |
|
||||||||||
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
||||||||||||||
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|