![]() |
![]() |
![]() |
|
|||||||||||||
| |
|
|
|
|
||||||||||||
| |
|
|
|
|
|
|
|
|||||||||
| |
|
|
|
|
|
|
||||||||||
| |
|
|||||||||||||||
| |
|
|||||||||||||||
| |
|
|
|
|||||||||||||
| |
|
|||||||||||||||
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SELECT ACID CAP WST STICKS SELECT ACID CAPS are 100%
active water-soluble tube sticks that release acid down-hole in producing and
water injection wells to remove carbonate scale and rust deposits. ACID CAPS are water soluble tubes filled with
100% active solid acid material. PRODUCT USES & ADVANTAGES SELECT ACID CAPS are
primarily used in water injection wells to remove carbonate scale and rust
deposits and lower injection pressures.
Injection pressure drops of several hundred PSI
have been observed following ACID CAP treatments. Some wells have gone on vacuum and taken
water by gravity. Success has also been
experienced in some producing oil wells, gas wells and water supply wells. SELECT ACID CAPS, after
removing the plastic wrapper, are dropped directly into the well or introduced
to the system through the water supply tank.
Dropping the stick directly into a well is best because not as much
dilution will occur. In a well with
tubing obstructions or small valve openings, ACID CAPS may be successfully used
by first dissolving the sticks in fresh water and then pumping or pouring the
solution into the well. ACID CAPS are very economical
(as compared to conventional scale removal operations) and can eliminate or
delay the need for HCl acid treatments. Continuous treatment with ACID CAPS (especially
after a conventional acid or clean-out job) can extend the time period between
future scale removal operations. ACID
CAPS are less corrosive to steel pipe than conventional liquid HCl acid jobs, because most of the acid generated by the
stick is released down-hole.
Conventional liquid HCl acid reacts with the
steel, rust and scale inside the pipe all the way down the well. ACID CAPS are safe to handle
and easy to use by less experienced field personnel; however, like all acids,
contact with eyes or skin should be avoided.
The plastic protective wrapper when removed before dropping stick can be
used as a protective glove while handling the stick. ACID CAPS are safe to use in cement lined tubing
and plastic line pipe. Continued
treatments over long periods of time through a by-pass feeder into cement lined
pipe should be avoided. TREATMENT DETERMINATION & PROCEDURE FOR WATER
REMOVAL The number of SELECT ACID
CAPS to be used is based on the number of feet of perforated interval or open
hole and severity of scale build-up.
Field tests indicate the best results were achieved by using large
initial slug treatment (1.8 to 5.4 lbs of stick per foot of interval) followed
by smaller periodic treatments (about half of the initial slug amount).
NOTE: A REACTIVE EQUIVALENCY of ACID CAPS vs. HCL ACID
RATIO was determined by field tests.
These tests indicated that about 10 ACID CAPS (1 Ό X 15) dropped in an
injection well, resulted in an equivalent pressure drop, as did using 120
gallons of 15% HCl acid. Liquid HCl acid
loses strength by reacting on the steel, scale and rust inside the pipe all the
way down the well while the sticks release most of their acid down-hole. THE MOST COMMON PROCEDURE is to shut-in the well, first remove the plastic
wrapper and then drop sticks through a lubricator and return well to
injection. This procedure is best for
open-hole, no rat-hole, low rate wells, or wells deeper than 3,300 feet. FOR SHALLOW PERFORATED WELLS WITH RAT-HOLE
drop sticks and leave well shut-in about 15 minutes or until sticks fall to the
perforations (whichever occurs first) then return well to injection. The time in minutes for the sticks to fall to
the perforations in a shut-in well is equal to the depth of perforations
divided by 110. (Time,min = Depth,ft / 110) PRODUCT SPECIFICATIONS The stick will normally
dissolve in 20 to 80 minutes (in moving water or when falling through water)
depending on temperature, salt content and relative water motion. ACID CAPS are 100% soluble in water. The melting point of the stick is 145ΊF. The stick will dissolve in water in wells
with BHT below 145Ί (just at a slower rate).
Lab tests indicate the dissolving rate in 50,000 PPM moving brine water
to be 105 minutes @ 100Ί, 38 minutes @ 120Ί, 7 minutes @ 140Ί, and 2 minutes @
180Ί. If slowing the dissolving rate is
desired, coat ACID CAPS with oil or grease.
The specific gravity is 1.23. The
falling rate through fresh water is approximately 110 feet per minute. Gas moving up tubing will often change
falling characteristics. PRODUCT PACKAGING
CAUTION: As with all industrial chemicals, contact with eyes
or skin should be avoided (see MSDS).
Wash thoroughly with water.
Sticks should be stored in a cool dry place. Always
remove stick from plastic bag before using.
Bag can be used as a glove to avoid contact. DISCLAIMER OF LIABILITY The information in this
bulletin is believed to be accurate, however all recommendations are made
without warranty since the conditions of use are beyond Select Industries, Inc.
control. Select Industries, Inc.
disclaims any liability in connection with the use of the information, and does
not warrant against infringement by reason of the use of any of its products
in combination with any other material or in any process. |
|
|
|
|
|
||||||||||||||
![]() |
|
|
|||||||||||||||
|
|
|
|
|
|
|
|
|
||||||||||
|
|
|
|
|
|
|
![]() |
|
||||||||||
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
||||||||||||
|
|
|
|
|
||||||||||||||
|
|
|
||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|